I�C was made to communicate over short distances between printed circuit boards and is a simple, 8-bit serial data bus. For the time being, it is not only PCB-mountable pressure sensors that utilize the I�C signal for data transfer, but additionally pressure sensors remote from customer electronics.
Remote sensors usually have the benefit of being less sensitive to contaminated or aggressive media and having the capacity to measure directly at the procedure. Regarding sensors mounted directly on the circuit board, the sensor element is, oftentimes, exposed directly to the medium. With remote sensors, steel or ceramic generally serve because the wetted surface.
I�C circuit
The I�C bus, alongside both supply lines, requires only two further lines:
SCL (serial clock line)
SDA (serial data line)
Additional possibilities through I�C
The I�C bus is a well-known standard in electronics, offering additional possibilities for communication with a pressure sensor than having an analogue signal:
In the data protocol, in addition to the pressure value, a temperature value and diagnostic information (for instance an integrity test of the data transfer) can be transmitted with a status byte.
Begging could be connected to a bus line as ?slaves? to the customer electronics that functions as a ?master?.
On the customer side, as opposed to using pressure sensors with analogue signals, the analogue-to-digital conversion of the pressure value for further signal processing is unnecessary because the pressure value has already been present in digital form. This plays a part in faster and easier signal processing.
The electronics for communication could be built with standard components readily available on the market.
Often, I�C signal pressure sensors may also be optimised to consume less energy, making them perfect for battery-powered applications. In the WIKA portfolio, for example, this pertains to the MPR-1 pressure sensor module.
Boundary conditions with the use of I�C
Since I�C is not a fieldbus, long wire lengths aren’t recommended. The utmost wire length depends, in detail, on the operating environment and the corresponding disturbing influences. I�C communication is most beneficial used in projects where the pressure sensor or the pressure sensor module is built-into the customer product and therefore protected against external influences. It will also be noted that with any digitally processed signal, the response time because of discrete-time sampling will be somewhat slower than for an analogue, continuous signal.
Note
Your contact person will be happy to help you with any further questions on digital interfaces.
Distributed Intelligence
Distributed Intelligence on the integration of pressure sensors into hydraulic systems
Fill below form and we will send you the whitepaper ?Distributed Intelligence?.
Self-sufficient -mail
Send